SureFood® GMO SCREEN 4plex BAR/NPTII/PAT/CTP2:CP4 EPSPS
Art. No.: S2127
Product info
Intended use
This kit can be used for screening of genetically modified organisms (GMOs) in food, feed and seeds. The multiplex test detects the following DNA-sequences:
- Phosphinothricin-Acetyltransferase gene (BAR) from Streptomyces hygroscopius
- Antibiotics-resistance gene Neomycin-Phosphotransferase (nptII)
- Phosphinothricin-Acetyltransferase gene (PAT) from Streptomyces viridiochromogenes
- The transition from CTP2 (Chloroplast-Transpeptide-signal sequence from Arabidopsis thaliana) to herbicide tolerance-gene CP4 EPSPS (5-Enolpyruvylshikimat-3-Phosphat Syntheses gene from Agrobacterium tumefaciens strain CP4)
The kit is according to German Food Law § 64 for the detection of genetically modified DNA sequences especially according to technical specification BVL L-00.00-124.
General Information
The real-time PCR assay can be used with established real-time PCR instruments, equipped for detection of four fluorescence emissions at 510 nm, 580 nm, 610 nm und 660 nm (FAM, VIC, ROX and Cy5) at the same time. The technical validation of instruments was performed on Roche LightCycler® 480 II, Applied Biosystems 7500, Bio-Rad CFX96 Agilent Mx3005P.
Accessories
Dear customers,
we now provide the documents for our products in an electronic format which include the Instructions for Use (IFU), Safety Data Sheets (SDS), Application notes and the Certificate of Analysis (CoA). For batches placed on the market after 1st of January 2024, you can find our documents on the eIFU portal congen.de/information.
Specifications | |
---|---|
Art. No | S2127 |
Test format | 100 reactions |
Sample preparation | For DNA-preparation of raw material the use of SureFood® PREP Basic (Art. No. S1052), SureFast® Mag PREP Food (Art. No. F1060) and for highly processed food and feed the use of SureFood® PREP Advanced (Art. No. S1053) is recommended. SureFood® PREP Add On (Art. No. S1055) is intended to be used for the extraction of DNA from raw materials as well as processed food and feed with sample weight of 2 g. It is used in conjunction with the SureFood® PREP Basic. |
LOD (Detection Limit) | The SureFood® GMO SCREEN 4plex BAR/NPTII/PAT/CTP2:CP4 EPSPS real time PCR has a limit of detection of ≤ 5 DNA copies. The assay limit of detection depends on sample matrix, processing grade, DNA preparation and DNA content. |
Files | |
---|---|
Instructions | German/English |
MSDS | Statement-MSDS-12-22-NG.pdf (English) |