RIDA® Aflatoxin column
Art. No.: R5001 / R5002
Product info
Intended use
RIDA® Aflatoxin columns (Art. No. R5001/R5002) are immunoaffinity columns for sample clean up prior to analysis of aflatoxins B1, B2, G1, G2 in food and feed. The columns are particularly suited for the clean up of difficult sampIes such as nuts, herbs, spices and tea leaves.
General Information
The RIDA® Aflatoxin columns are usable in combination with enzyme immunoassay RIDASCREEN® Aflatoxin Total (Art. No. R4701) for the quantitative determination of aflatoxins B1, B2, G1, G2.
Benefit:
- The columns are particularly suited for the clean up of difficult sampIes such as nuts, herbs, spices and tea leaves.
Dear customers,
we have started to provide the documents for our products in an electronic format. These are the Instructions for Use (IFU), the Safety Data Sheets (SDS) and the Certificate of Analysis (CoA). For batches placed on the market after 01 January 2024, you can find our documents on the eIFU portal eifu.r-biopharm.com/food.
Specifications | |
---|---|
Art. No | R5001 / R5002 |
Test format | 10 immunoaffinity columns (1 ml format) (R5001), 50 immunoaffinity columns (1 ml format) (R5002) |
Sample preparation | The samples should be stored in a cool place, protected against light. Aflatoxins are light sensitive, therefore, avoid exposure of the samples and sample extracts to direct light. |
LOD (Detection Limit) | Depending on the applied sample quantity and the detection method (e.g. for herbs, spices and tea leaves) with subsequent analysis in the RIDASCREEN® Aflatoxin Total Test approx. 250 ng/kg (ppt). |
Validated matrices | Feed, the columns are particularly suited for the clean up of difficult samples such as nuts, herbs, spices and tea leaves. |
Detected analyte | Aflatoxin in feed and as well as in nuts, herbs, spices and tea leaves. |
Available application notes | An additional application note for green coffee for analysis with the RIDASCREEN® Aflatoxin Total (Art. No. R4701) is available on request. Please contact your local distributor. |
Evaluation | In order to obtain the aflatoxin concentration actually contained in a sample the concentration read from the calibration curve has to be multiplied by the corresponding dilution factor. The immunoaffinity columns are only suitable for sample clean-up. For the evaluation the RIDASCREEN® Aflatoxin Total (Art. No. R4701) is required for the quantitative determination of the aflatoxins B1, B2, G1 and G2. |