AFLARHONE® WIDE

Art. No.: RBRP116

  1. Home
  2. /
  3. Products
  4. /
  5. AFLARHONE® WIDE

Analytes

Produktinformation

AFLARHONE® WIDE

Art. No.: RBRP116

Bestellen

Verwendungszweck

Immunoaffinity columns for use in conjunction with an HPLC or LC-MS/MS for detection of aflatoxins
B1, B2, G1, G2, M1 and M2 in a wide range of commodities.

Allgemeines

The columns contain a gel suspension of monoclonal antibody specific to the toxins of interest. Following extraction of the toxins the sample extract is filtered, diluted and passed slowly through the immunoaffinity column. Any toxins which are present in the sample are retained by the antibody within the gel suspension. The column is washed to remove unbound material and the toxins are then released from the column following elution with solvent. The eluate is collected prior to analysis by HPLC or LC-MS/MS. Aflatoxins are required to be derivatised when analysed by HPLC. The total extraction and clean-up time takes approximately 20 minutes to perform. The result is improved clean-up and concentration of the toxins from food and feed samples giving a much cleaner chromatogram and therefore providing more accurate and sensitive detection. The columns also have the added advantage that they can be automated for large scale analysis of samples.

High quality:

  • Exceeds Official Method criteria
  • Manufactured with bespoke automated systems ensuring product consistency also providing unique batch number etching

Value for money:

  • Delivering quality at an acceptable cost
  • Outstanding technical support from an expert team
  • Produced in large batch sizes reducing in-house quality testing

Reliable:

  • Consistently high level performance
  • Global mycotoxin test kit supplier for over 35 years

Zubehör

Liebe Kunden,

wir haben damit begonnen, die Dokumente zu unseren Produkten in einem elektronischen Format bereitzustellen. Hierbei handelt es sich um die Gebrauchsanweisung (IFU), die Sicherheitsdatenblätter (SDS), Application notes sowie das Certificate of Analysis (CoA). Für Chargen, die ab dem 01. Juni 2023 in Verkehr gebracht wurden, finden Sie unsere Dokumente auf dem eIFU Portal eifu.r-biopharm.com.

Spezifikationen
Art. Nr.RBRP116
Testformat25 columns (3 ml format) (RBRP116/25)
100 columns (3 ml format) (RBRP116/100)
500 columns (3 ml format) (RBRP116/500)
ProbenvorbereitungA representative sample should be obtained by following an officially recognised sampling procedure. Sample is extracted using solvent, (Extracting solvent can vary depending on commodity analysed) filtered and diluted ready for applying to the immunoaffinity column.
LOD (Nachweisgrenze)Information provided is typical LOD obtained by R-Biopharm. Please note that this is dependant on method, LC conditions and equipment used.

B1 0.031 ng/ml,
B2 0.016 ng/ml,
G1 0.031 ng/ml,
G2 0.004 ng/ml
Vorhandene Application Notes

Methods are available for all matrices covered by legislation as well as additional commodities. Please contact your local R-Biopharm distributor for further information.

Detected analyte
Aflatoxin B1, Aflatoxin B2, Aflatoxin G1, Aflatoxin G2, Aflatoxin M1, Aflatoxin M2 and Sterigmatocystin. May also cross react with other metabolites.

AuswertungHPLC or LC-MS/MS.