Purification columns
Efficient sample clean-up
- Home
- /
- Technologies
- /
- Purification columns
Purification columns
When using analysis methods such as HPLC, GC and LC-MS/MS, purification of the sample is of great importance.
For the sample clean-up / purification for mycotoxin analysis, we offer IAC and SPE columns. Immunoaffinity columns (e.g. RIDA®, EASI-EXTRACT®, PREP®) enable efficient mycotoxin clean-up for all kinds of commodities prior to HPLC, LC-MSMS or ELISA. PuriTox solid phase extraction columns enable mycotoxin clean-up prior to TLC, HPLC, GC or LC-MSMS.
Immunoaffinity columns
Immunoaffinity columns (IAC) are the standard method of choice for sample preparation of mycotoxins prior to HPLC, GC and LC-MS/MS. They are the ideal clean-up tools for the analysis of complex or colored food and feed samples. Monoclonal antibodies selectively isolate and concentrate the mycotoxin of interest, removing any interfering components from the sample. This highly specific clean-up removes interference and results in a clean eluate which removes the need to use matrix matched or isotopic labelled standards. It improves chromatography and ultimately lowers limits of detection. R-Biopharm offers IACs produced by their partner R-Biopharm Rhône. R-Biopharm Rhône IACs are recognized in official methods from AOAC and CEN, exceeding specifications and EU Method Performance Criteria.
Solid phase extraction columns
Solid phase extraction columns (SPE) contain solid adsorbents which bind to interfering components and pigments. Thus, the columns reduce background interference, therefore producing better chromatography and improving accuracy of results. The PuriTox products by R-Biopharm Rhône allow a simultaneous detection of multiple mycotoxins, offering a simple, fast and cost-effective screening method.
Product portfolio
Product | Description | No. of tests/amount | Art. No. |
---|---|---|---|
QualiT Pure™ Multi-tox MS |
Solid phase clean-up column for the purification of multi-mycotoxins. Read more |
50 columns (syringe format) | TC-QP1100-50 |
IMMUNOPREP® ONLINE DEOXYNIVALENOL |
Online immunoaffinity cartridges used in conjunction with the CHRONECT Symbiosis RIDA®CREST system for the automated clean-up and analysis of deoxynivalenol prior to HPLC or LC-MS/MS. Read more |
RBRP902/48: 48 cartridges | RBRP902/48 |
IMMUNOPREP® ONLINE OCHRATOXIN |
Online immunoaffinity cartridges used in conjunction with the CHRONECT Symbiosis RIDA®CREST system for the automated clean-up and analysis of ochratoxin A prior to HPLC or LC-MS/MS. Read more |
RBRP901/48: 48 cartridges, RBRP901: 96 cartridges |
RBRP901 / RBRP901/48 |
IMMUNOPREP® ONLINE AFLATOXIN M1 |
Online immunoaffinity cartridges used in conjunction with the CHRONECT Symbiosis RIDA®CREST system for the automated clean-up and analysis of aflatoxins M1 prior to HPLC or LC-MS/MS. Read more |
RBRP904/48: 48 cartridges | RBRP904/48 |
IMMUNOPREP® ONLINE AFLATOXIN |
Online immunoaffinity cartridges used in conjunction with the CHRONECT Symbiosis RIDA®CREST system for the automated clean-up and analysis of aflatoxins B1, B2, G1 and G2 prior to HPLC or LC-MS/MS. Read more |
RBRP900/48: 48 cartridges, RBRP900: 96 cartridges |
RBRP900 / RBRP900/48 |
11⁺Myco MS-PREP® |
Multi-mycotoxin immunoaffinity columns for simultaneous detection of aflatoxins B1, B2, G1, G2, ochratoxin A, fumonisins B1 and B2, Deoxynivalenol, Zearalenone, T-2 and HT-2 in a wide range of commodities in conjunction with LC-MS/MS. Read more |
RBRP128: 10 immunoaffinity columns (3 ml format), RBRP128B: 50 immunoaffinity columns (3 ml format) |
RBRP128 / RBRP128B |
EASI-EXTRACT® CITRININ |
Immunoaffinity columns for use in conjunction with an HPLC or LC-MS/MS for detection of citrinin in a wide range of commodities. Read more |
10 columns (3 ml format) (RBRDP126), 25 columns (3 ml format) (RBRP126) |
RBRDP126 / RBRP126 |
PuriTox Total Myco-MS |
Solid phase clean-up columns for the purification of 11 mycotoxins. PuriTox Total Myco-MS® (Art. No. TC-MT3000) can be used for the simultaneous detection of aflatoxins B1, B2, G1, G2, ochratoxin A, fumonisins B1 and B2, deoxynivalenol, zearalenone, … Read more |
25 solid phase clean-up columns (syringe format) | TC-MT3000 |
AFLAPREP® M WIDE |
The procedure is based on monoclonal antibody technology, which makes the test highly specific, sensitive, rapid and simple to perform. Immunoaffinity columns for use in conjunction with an HPLC or LC-MS/MS for detection of aflatoxin M1 in milk and … Read more |
10 columns (3 ml format) (RBRP124), 50 columns (3 ml format) (RBRP124B) |
RBRP124 / RBRP124B |
AOF MS-PREP® |
AOF MS-PREP® immunoaffinity columns contain highly specific monoclonal antibodies directed against aflatoxin, ochratoxin A and fumonisin. The columns lead not only to a clean-up of the sample but also to a selective purification of the mycotoxins. … Read more |
RBRP115: 10 immunoaffinity columns (3 ml format), RBRP115B: 50 immunoaffinity columns (3 ml format) |
RBRP115 / RBRP115B |
OCHRAPREP® |
Immunoaffinity columns for use in conjunction with HPLC or LC-MS/MS for detection of ochratoxin A in a wide range of commodities. Read more |
10 columns (3 ml format) (RBRP14) 50 columns (3 ml format) (RBRP14B) 500 columns (3ml format) (RBRP14/500) |
RBRP14 / RBRP14B |
EASI-EXTRACT® ZEARALENONE |
Immunoaffinity columns for use in conjunction with HPLC or LC-MS/MS for detection of zearalenone in a wide range of commodities. Read more |
10 columns (3 ml format) (RBRRP91), 50 columns (3 ml format) (RBRRP90) |
RBRRP91 / RBRRP90 |
EASI-EXTRACT® T-2 and HT-2 |
Immunoaffinity columns for use in conjunction with an HPLC or LC-MS/MS for detection of T-2 and HT-2 toxins in a wide range of commodities. Read more |
10 columns (3 ml format) (RBRP43), 50 columns (3 ml format) (RBRP43B) |
RBRP43 / RBRP43B |
EASIMIP™ PATULIN |
Molecularly Imprinted Polymer (MIP) columns for use in conjunction with an HPLC for detection of patulin in apple juice and apple purée. Read more |
RBRP250: 10 columns (3 ml format), RBRP250B: 50 columns (3 ml format) |
RBRP250 / RBRP250B |
RIDA® Ochratoxin A column |
RIDA® Ochratoxin A column are immunoaffinity columns for sample clean up prior to analysis of Ochratoxin A in food and feed. Read more |
10 immunoaffinity columns | R1303 |
AFLAOCHRA PREP® |
Multi-mycotoxin immunoaffinity columns for simultaneous detection of aflatoxins B1, B2, G1, G2 and ochratoxin A in a wide range of commodities in conjunction with HPLC or LC-MS/MS. Read more |
RBRP89: 10 immunoaffinity columns (1 ml format), RBRP89B: 50 immunoaffinity columns (1 ml format) |
RBRP89 / RBRP89B |
DZT MS-PREP® |
DZT MS-PREP® immunoaffinity columns contain highly specific monoclonal antibodies directed against DON, zearalenone, T-2 and HT-2 toxin. The columns lead not only to a clean-up of the sample but also to a selective purification of the mycotoxins. … Read more |
RBRP73: 10 immunoaffinity columns (1 ml format), RBRP73B: 50 immunoaffinity columns (1 ml format) |
RBRP73 / RBRP73B |
AO ZON PREP® |
Multi-mycotoxin immunoaffinity columns for simultaneous detection of aflatoxins B1, B2, G1, G2, ochratoxin A and zearalenone in a wide range of commodities in conjunction with HPLC or LC-MS/MS. Read more |
RBRP112: 10 immunoaffinity columns (3 ml format), RBRP112B: 50 immunoaffinity columns (3 ml format) |
RBRP112 / RBRP112B |
FUMONIPREP® |
Immunoaffinity columns are used in conjunction with HPLC or LC-MS/MS for detection of fumonisins B1 and B2 in a wide range of commodities. Read more |
10 columns (3 ml format) (RBRDP31), 50 columns (3 ml format) (RBRP31B) |
RBRDP31 / RBRP31B |
DONPREP® |
Immunoaffinity columns for use in conjunction with an HPLC or LC-MS/MS for detection of deoxynivalenol in a wide range of commodities. Read more |
10 columns (3 ml format) (RBRP50) 50 columns (3 ml format) (RBRP50B) 500 columns (3 ml format) (RBRP50/500) |
RBRP50 / RBRP50B |
EASI-EXTRACT® AFLATOXIN |
Immunoaffinity columns for use in conjunction with an HPLC or LC-MS/MS for detection of aflatoxins B1, B2, G1, G2, M1 and M2 in a wide range of commodities. Read more |
10 columns (3 ml format) (RBRRP71) 50 columns (3 ml format) (RBRRP70N) 500 columns (3 ml format) (RBRP70N/500) |
RBRRP71 / RBRRP70N |
RIDA® Aflatoxin column |
RIDA® Aflatoxin columns (Art. No. R5001/R5002) are immunoaffinity columns for sample clean up prior to analysis of aflatoxins B1, B2, G1, G2 in food and feed. The columns are particularly suited for the clean up of difficult sampIes such as nuts, … Read more |
10 immunoaffinity columns (1 ml format) (R5001), 50 immunoaffinity columns (1 ml format) (R5002) |
R5001 / R5002 |
PuriTox Aflatoxin |
Solid phase clean-up columns for the purification of aflatoxins B1, B2, G1 and G2 from peanuts. Read more |
50 columns (syringe format) | RBRP25 |
AFLAPREP® |
The procedure is based on monoclonal antibody technology, which makes the test highly specific, sensitive, rapid and simple to perform. Read more |
10 columns (1 ml format) (RBRDP07) 50 columns (1 ml format) (RBRP07) 500 columns ( 1ml format) (RBRP07/500) |
RBRDP07 / RBRP07 |
PuriTox Trichothecene |
Solid phase clean-up columns for the purification of cereal samples to detect trichothecenes. PuriTox Trichothecene can be used for the simultaneous detection of type A and B trichothecenes by GC and LC-MS/MS. Read more |
25 solid phase clean-up columns (syringe format) | TC-T220 |
PuriTox AflaZON |
Solid phase clean-up columns for the purification of aflatoxins and zearalenone from cereals. Read more |
25 solid phase clean-up columns (syringe format) | TC-M160 |
Product | Description | No. of tests/amount | Art. No. |
---|---|---|---|
RIDA® C18 column |
The solid phase extraction (SPE) with RIDA® C18 columns is an efficient technique for a fast and selective sample preparation, especially for the RIDASCREEN® and EuroProxima anabolic- and hormone enzyme immunoassays. Read more |
100 x C18 columns (100 mg/ml column reservoir) | R2002 |
Product | Description | No. of tests/amount | Art. No. |
---|---|---|---|
EASI-EXTRACT® BIOTIN |
Immunoaffinity columns for use in conjuntion with an HPLC or LC-MS/MS system for detection of biotin in a wide range of commodities. Read more |
RBRP82 = 10 immunoaffinity columns with 3 ml format. RBRP82B = 50 immunoaffinity columns with 3 ml format. |
RBRP82 / RBRP82B |
EASI-EXTRACT® FOLIC ACID |
Immunoaffinity columns for use in conjunction with an HPLC or LC/MS-MS system for detection of folic acid in a wide range of commodities. Read more |
RBRP81 = 10 immunoaffinity columns with 3 ml format. RBRP81B = 50 immunoaffinity columns with 3 ml format. |
RBRP81 / RBRP81B |
EASI-EXTRACT® VITAMIN B12 (LGE) |
Immunoaffinity columns for use in conjunction with an HPLC or LC-MS/MS system for detection of vitamin B12 in a wide range of commodities. Novel immunoaffinity columns with built-in reservoir for detection of vitamin B12 in a wide of range … Read more |
RBRP88 = 10 immunoaffinity columns with 10 ml format. RBRP88B = 50 immunoaffinity columns with 10 ml format. |
RBRP88 / RBRP88B |
EASI-EXTRACT® VITAMIN B12 |
Immunoaffinity columns for use in conjunction with an HPLC or LC-MS/MS system for detection of vitamin B12 in a wide range of commodities. Read more |
RBRP80 = 10 immunoaffinity columns with 3 ml format. RBRP80B = 50 immunoaffinity columns with 3 ml format. |
RBRP80 / RBRP80B |
EASI-EXTRACT® MULTI-VIT B (LGE) |
Immunoaffinity columns for use in conjunction with an HPLC or LC-MS/MS system for detection of biotin, folic acid and vitamin B12 in a wide range of commodities. Read more |
RBRP183 = 10 immunoaffinity columns with 10 ml format. RBRP183B = 50 immunoaffinity columns with 10 ml format. Capacity = 0.45 µg biotin, 0.5 µg folic acid, 1 µg vitamin B12. |
RBRP183 / RBRP183B |